Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 7.222
Filtrar
1.
BMJ Open ; 14(4): e079197, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38569682

RESUMO

BackgroundEndovascular thrombectomy is the recommended treatment for acute ischaemic stroke, but the optimal blood pressure management strategy during the procedure under general anaesthesia remains controversial. In this study protocol, we propose an intraoperative intensive blood pressure range (110-140 mm Hg systolic blood pressure) based on a retrospective analysis and extensive literature review. By comparing the outcomes of patients who had an acute ischaemic stroke undergoing mechanical thrombectomy under general anaesthesia with standard blood pressure management (140-180 mm Hg systolic blood pressure) versus intensive blood pressure management, we aim to determine the impact of intraoperative intensive blood pressure management strategy on patient prognosis. METHODS AND ANALYSIS: The study is a double-blinded, randomised, controlled study, with patients randomised into either the standard blood pressure management group or the intensive blood pressure management group. The primary endpoint of the study will be the sequential analysis of modified Rankin Scale scores at 90 days after mechanical thrombectomy. ETHICS AND DISSEMINATION: The study has been approved by the ethics committee of Shanghai Changhai Hospital with an approval number CHEC2023-015. The results of the study will be published in peer-reviewed international journals. TRIAL REGISTRATION NUMBER: ChiCTR2300070764.


Assuntos
Isquemia Encefálica , Procedimentos Endovasculares , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Acidente Vascular Cerebral/cirurgia , Isquemia Encefálica/cirurgia , Pressão Sanguínea/fisiologia , Estudos Prospectivos , Estudos Retrospectivos , China , Trombectomia/métodos , Resultado do Tratamento , Anestesia Geral/métodos , Procedimentos Endovasculares/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto
2.
BMC Anesthesiol ; 24(1): 135, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594662

RESUMO

BACKGROUND: Early water intake has gained widespread attention considering enhanced recovery after surgery (ERAS). In the present systematic evaluation and meta-analysis, we assessed the effects of early water intake on the incidence of vomiting and aspiration in adult patients who received general anaesthesia on regaining consciousness during the resuscitation period. OBJECTIVE: To systematically analyse the results of randomised controlled trials on early postoperative water intake in patients who underwent different types of surgery under general anaesthesia, both at home and abroad, to further explore the safety and application of early water intake and provide an evidence-based foundation for clinical application. DESIGN: Systematic review and meta-analysis. METHODS: To perform the systematic evaluation and meta-analysis, we searched the Web of Science, CINAHL, Embase, PubMed, Cochrane Library, Sinomed, China National Knowledge Infrastructure (CNKI), Wanfang, and Vipshop databases to identify randomised controlled trial studies on early water intake in adult patients who received general anaesthesia. RESULTS: Herein, we included 10 publications with a total sample size of 5131 patients. Based on statistical analysis, there was no statistically significant difference in the incidence of vomiting (odds ratio [OR] = 0.81; 95% confidence interval [CI] [0.58-1.12]; p = 0.20; I-squared [I2] = 0%) and aspiration (OR = 0.78; 95%CI [0.45-1.37]; p = 0.40; I2 = 0%) between the two groups of patients on regaining consciousness post-general anaesthesia. CONCLUSION: Based on the available evidence, early water intake after regaining consciousness post-anaesthesia did not increase the incidence of adverse complications when compared with traditional postoperative water abstinence. Early water intake could effectively improve patient thirst and facilitate the recovery of gastrointestinal function.


Assuntos
Anestesia Geral , Ingestão de Líquidos , Adulto , Humanos , Anestesia Geral/efeitos adversos , Anestesia Geral/métodos , Vômito , Período Pós-Operatório , China
3.
BMC Anesthesiol ; 24(1): 157, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38658856

RESUMO

BACKGROUND: The main cause of anesthesia-related deaths is the failure to manage difficult airways. Difficult laryngoscopic exposure is a major cause of unsuccessful management of difficult airways. Inadequate preoperative airway assessment hinders the clinical management of difficult airways cases, emphasizing the critical need for accurate identification of difficult airways. Currently, no definitive and reliable indicators are available to predict a difficult airway. Our study aims to predict laryngoscope exposure risk factors by combining ultrasonically measured upper airway anatomic parameters with physical examination indicators. METHODS: Patients aged 18 to 75 years, classified as American Standards Association (ASA) I-III, and scheduled for elective general anesthesia with endotracheal intubation were included. All patients received the upper airway and ultrasonographic measurements. After anesthesia induction, laryngoscope exposure was analyzed using the Cormack-Lehane grading system, with Grades III and IV as indicative of difficult laryngoscopy. Univariate and multivariate logistic regression analyses were performed to identify reliable indicators for predicting difficult laryngoscopy. Receiver Operating Characteristic (ROC) curve analysis was utilized to assess the predictive performance of each indicator. RESULTS: A total of 1120 patients finished the study, with 710 cases found in Grade I laryngoscopic exposure group, 360 cases in Grade II group, and 50 cases in Grade III group. There was no case observed in Grade IV group, thereby resulting in an incidence of difficult laryngoscopy of 4.46%. Univariate logistic regression analysis revealed that several parameters including age, Body Mass Index (BMI), neck circumference, neck mobility, snoring intensity, as well as ultrasound measurements of the pre-epiglottic space and thyromental distance were identified as significant risk factors for difficult laryngoscopy (P < 0.05). Among these, BMI, and neck circumference exhibited notable predictive value, with Area Under The Curve (AUC) values of 0.746 (95%CI 0.649-0.842) and 0.732 (95%CI 0.638-0.827), respectively. Neck mobility was also identified as an independent risk factor for predicting difficult laryngoscopy (P = 0.009) in multivariate logistic regression analysis, with an AUC of 0.672 (0.562-0.782) in the ROC curve. CONCLUSIONS: Our findings revealed a direct correlation between difficult laryngoscopy and age, BMI, neck circumference, neck mobility, snoring intensity, as well as ultrasound measurements of the pre-epiglottic space and thyromental distance. Furthermore, neck mobility was identified as an independent predictive factor. TRIAL REGISTRATION: The trial was registered prior to patient enrollment at clinicaltrials.gov (register no. ChiCTR2100053826, Date of registration: November 30, 2021).


Assuntos
Intubação Intratraqueal , Laringoscopia , Ultrassonografia , Humanos , Laringoscopia/métodos , Pessoa de Meia-Idade , Estudos Prospectivos , Masculino , Feminino , Adulto , Idoso , Intubação Intratraqueal/métodos , Ultrassonografia/métodos , Fatores de Risco , Adulto Jovem , Anestesia Geral/métodos , Adolescente , Índice de Massa Corporal
4.
Klin Monbl Augenheilkd ; 241(4): 571-573, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38653301

RESUMO

BACKGROUND: As studies have shown a reduction in the occurrence of the oculocardiac reflex with the addition of local anaesthesia, we changed our care regime accordingly a few years ago. To promote and establish better patient care, we retrospectively analysed the files of our patients who underwent strabismus surgery from 2013 to 2021 in order to compare strabismus surgery under general anaesthesia with and without local anaesthetics in a routine clinical setting. PATIENTS AND METHODS: Data from 238 adult patients who had undergone strabismus surgery could be extracted from the files: G1: n = 102, only general anaesthesia; G2: n = 136, preoperative application of tetracaine eye drops and intraoperative subtenon lidocaine/levobupivacaine in addition to general anaesthesia. We compared the two groups in regard to the frequency of oculocardiac reflex, the amount of atropine needed to treat, as well as the amount of antiemetic and analgesic medication given, and time spent in the recovery room. RESULTS: Mean age of G1 was 50 years and 52 years in G2. There was no significant difference between the kind of surgeries (recessions/resections), the number of patients who had undergone a reoperation, or the duration of the operations. Adding local anaesthetics resulted in significantly less occurrence of oculocardiac reflex (p = 0.009), a reduction in the need for atropine, analgesic, or antiemetic medication, as well as reduced time in the recovery room. CONCLUSION: As this increases patient safety and comfort and is cost-effective (less time in the recovery room), we recommend adding perioperative local anaesthesia to strabismus surgery performed under general anaesthesia.


Assuntos
Anestesia Geral , Anestésicos Locais , Reflexo Oculocardíaco , Estrabismo , Humanos , Estrabismo/cirurgia , Anestesia Geral/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Anestésicos Locais/administração & dosagem , Adulto , Estudos Retrospectivos , Reflexo Oculocardíaco/efeitos dos fármacos , Anestesia Local/métodos , Lidocaína/administração & dosagem , Cuidados Intraoperatórios/métodos , Cuidados Pré-Operatórios/métodos , Tetracaína/administração & dosagem , Adulto Jovem , Idoso , Procedimentos Cirúrgicos Oftalmológicos/métodos , Resultado do Tratamento
5.
BMC Anesthesiol ; 24(1): 100, 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38475719

RESUMO

BACKGROUND: Mediastinal tumors pose a challenging respiratory and circulatory management during anesthesia procedures, there is a risk of circulatory collapse or complete airway obstruction, which in severe cases can lead to cardiac arrest. We reported a case of anesthetic management using a bronchial blocker placed outside the tracheal tube. In this case report, the patient's trachea was so severely compressed that the airway was extremely narrow, only 4 mm at its narrowest point. By reporting the anesthetic management of this patient, we intend to provide an unusual approach for airway management. CASE PRESENTATION: A 52-year-old male patient was admitted to the hospital due to cough and expectoration for one year. Additionally, the patient experienced chest tightness and asthma after physical activity. The enhanced computed tomography revealed there existed an irregular soft tissue mass in the right upper mediastinum, which significantly compressed the trachea and esophagus. The results of the mediastinal puncture pathology showed the presence of mesenchymal tumors. According to the results above, the patient was diagnosed with a mediastinal tumor and scheduled to undergo tumor resection under general anesthesia. We used a bronchial occluder outside the tracheal tube for general anesthesia. After surgery, the patient received thorough treatment and was subsequently discharged from the hospital. CONCLUSION: In patients with severe airway compression from a mediastinal tumor airway compression, positioning a bronchial occluder externally to the tracheal tube is an effective method of airway management. However, we still need more clinical practice to help the process become more standardized.


Assuntos
Anestésicos , Neoplasias do Mediastino , Masculino , Humanos , Pessoa de Meia-Idade , Neoplasias do Mediastino/cirurgia , Brônquios , Traqueia , Anestesia Geral/métodos
6.
PLoS One ; 19(3): e0289519, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38427628

RESUMO

BACKGROUND: Patients diagnosed with stage III breast cancer often undergo surgery, radiation therapy, and chemotherapy as part of their treatment. The choice of anesthesia technique during surgery has been a subject of interest due to its potential association with immune changes and prognosis. In this study, we aimed to compare the mortality rates between stage III breast cancer patients undergoing surgery with propofol-based intravenous general anesthesia and those receiving inhaled anesthetics. METHODS: Using data from Taiwan's National Health Insurance Research Database and Taiwan Cancer Registry, we identified a cohort of 10,896 stage III breast cancer patients. Among them, 1,506 received propofol-based intravenous anesthetic maintenance, while 9,390 received inhaled anesthetic maintenance. To ensure comparability between the two groups, we performed propensity-score matching. RESULTS: Our findings revealed a significantly lower mortality rate in patients who received inhaled anesthetics compared to those who received propofol-based intravenous anesthesia. Sensitivity analysis further confirmed the robustness of our results. CONCLUSIONS: This study suggests that inhaled anesthesia technique is associated with a lower mortality rate in clinical stage III breast cancer. Further research is needed to validate and expand upon these results.


Assuntos
Anestésicos Inalatórios , Neoplasias da Mama , Propofol , Humanos , Feminino , Propofol/uso terapêutico , Neoplasias da Mama/tratamento farmacológico , Anestésicos Intravenosos , Anestesia Intravenosa , Anestesia Geral/métodos
7.
Neurodiagn J ; 64(1): 11-23, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38437032

RESUMO

Transcranial motor-evoked potentials (TcMEPs) play an integral role in assessing motor tract function in surgical procedures where motor function is at risk. However, transcranial stimulation creates a risk for oral trauma. Several studies have reported on distinct factors that can influence the rate of TcMEP-induced oral trauma, but little is known about how an anesthetic regimen can influence this rate. In this retrospective review, we investigated the incidence of oral injury under total intravenous anesthesia (TIVA) and balanced anesthesia in 66,166 cases from 2019 to 2021. There were 295 oral injuries in our sample, yielding an incidence of 0.45%, which is in line with ranges reported in the literature. A total of 222 of the injured patients were sedated with balanced anesthesia, while the remaining 73 were under TIVA anesthetics. This difference in distribution was statistically significant (p < 0.0002). Our findings suggest TIVA is associated with lower risk of oral trauma when TcMEPs are monitored, thereby improving patient safety.


Assuntos
Anestésicos , Humanos , Incidência , Anestésicos/farmacologia , Potencial Evocado Motor/fisiologia , Anestesia Geral/métodos , Estudos Retrospectivos
8.
Sci Rep ; 14(1): 6441, 2024 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-38499567

RESUMO

Inadequate antinociception during skull pin fixation may cause hemodynamic instability in intracranial surgery. The optimal concentration of remifentanil to provide adequate antinociception and stable hemodynamics during skull pin fixation under analgesia nociception index monitoring is unknown. This study is to assess the 90% effective concentration of remifentanil for skull pin fixation under hemodynamic and analgesia nociception index monitoring. Twenty-six patients were enrolled for intracranial surgery, anesthesia was induced and maintained under total intravenous anesthesia using target-controlled infusion for remifentanil and propofol under analgesia nociception index and bispectral index monitoring. Skull pin fixation was performed at different effect-site concentrations of remifentanil required for Dixon's up-and-down method with a step size of 0.5 ng/ml under bispectral index 40-60. Inadequate antinociception is defined when either ANI < 30 or > 20% in hemodynamic changes from baseline (e.g. heart rate > 100 beats/min, or blood pressure > 180/100 mmHg) and the effect-site concentration of remifentanil is considered as failure. It is considered success as ANI > 30 and < 20% hemodynamic changes from baseline simultaneously. Seven pairs of failure/success were used for probit analysis. The 90% effective concentration of remifentanil for skull pin fixation with adequate antinociception and hemodynamic stability was 4.7 ng/ml.


Assuntos
Analgesia , Propofol , Humanos , Remifentanil/farmacologia , Anestésicos Intravenosos/farmacologia , Nociceptividade , Piperidinas/farmacologia , Dor/tratamento farmacológico , Propofol/farmacologia , Hemodinâmica , Analgesia/métodos , Anestesia Geral/métodos , Crânio/cirurgia
9.
BMC Anesthesiol ; 24(1): 70, 2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38395779

RESUMO

BACKGROUND: Propofol formulated with medium- and long-chain triglycerides (MCT/LCT propofol) has rapidly replaced propofol formulated with long-chain triglycerides (LCT propofol). Despite this shift, the modified Marsh and Schnider pharmacokinetic models developed using LCT propofol are still widely used for target-controlled infusion (TCI) of propofol. This study aimed to validate the external applicability of these models by evaluating their predictive performance during TCI of MCT/LCT propofol in general anesthesia. METHODS: Adult patients (n = 48) undergoing elective surgery received MCT/LCT propofol via a TCI system using either the modified Marsh or Schnider models. Blood samples were collected at various target propofol concentrations and at specific time points, including the loss of consciousness and the recovery of consciousness (13 samples per patient). The actual plasma concentration of propofol was determined using high-performance liquid chromatography. The predictive performance of each pharmacokinetic model was assessed by calculating four parameters: inaccuracy, bias, divergence, and wobble. RESULTS: Both the modified Marsh and Schnider models demonstrated predictive performances within clinically acceptable ranges for MCT/LCT propofol. The inaccuracy values were 24.4% for the modified Marsh model and 26.9% for the Schnider model. Both models showed an overall positive bias, 16.4% for the modified Marsh model and 16.6% for the Schnider model. The predictive performance of MCT/LCT propofol was comparable to that of LCT propofol, suggesting formulation changes might exert only a minor impact on the reliability of the TCI system during general anesthesia. Additionally, both models exhibited higher bias and inaccuracy at target concentrations ranging from 3.5 ~ 5 ug/ml than at concentrations between 2 ~ 3 ug/ml. CONCLUSIONS: The modified Marsh and Schnider models, initially developed for LCT propofol, remain clinically acceptable for TCI with MCT/LCT propofol. TRIAL REGISTRATION: This study was registered at the Clinical Research Information Service of the Korean National Institute of Health ( https://cris.nih.go.kr ; registration number: KCT0002191; 06/01/2017).


Assuntos
Propofol , Adulto , Humanos , Propofol/farmacocinética , Anestésicos Intravenosos/farmacocinética , Reprodutibilidade dos Testes , Áreas Alagadas , Infusões Intravenosas , Anestesia Geral/métodos , Triglicerídeos
10.
Clin Ther ; 46(3): 252-257, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38368167

RESUMO

PURPOSE: During the induction of general anesthesia, opioids and endotracheal intubation may cause coughing. This study aimed to investigate the safety and effectiveness of an optimized drug induction scheme for general anesthesia to prevent coughing in patients. METHODS: A total of 220 patients aged 18 to 65 years who underwent surgery under general anesthesia with endotracheal intubation were randomly assigned to two groups, each with 110 patients. One group was administered a divided sufentanil bolus (group A) and the other with a single sufentanil bolus (group B). Anesthesia induction was performed according to the drug induction scheme of 1st, 2nd, and 3rd minutes. The primary outcome was a coughing episode associated with the administration of opioids during anesthesia induction. We also recorded the pain associated with drug injection, hemodynamics, and blood oxygen saturation during the induction of anesthesia. FINDINGS: All patients were included in the final statistical analysis. Compared with group B, the incidence of opioid induced cough (OIC) was significantly higher in group A (9.1% vs. 0, P = 0.001). There was no cough reaction of tracheal intubation in either group. There was no severe pain due to propofol and rocuronium injection in either group (P > 0.05). The mean arterial pressure (MAP), heart rate (HR), and peripheral oxygen saturation (SpO2) values were within the normal range at each time point during the induction period in both groups. IMPLICATIONS: According to the optimized 1st, 2nd, and 3rd minutes anesthesia induction regimen, with a single final intravenous bolus of sufentanil after the diluted rocuronium bromide administration, no sufentanil and tracheal intubation induced coughing reactions were observed. TRIAL REGISTRATION: The study protocol was registered in the Chinese Clinical Trial Registry (ChiCTR2200062749, http://www.chictr.org.cn/showproj.aspx?proj=175018) on August 17, 2022.


Assuntos
Analgésicos Opioides , Sufentanil , Humanos , Sufentanil/efeitos adversos , Estudos Prospectivos , Analgésicos Opioides/uso terapêutico , Anestesia Geral/efeitos adversos , Anestesia Geral/métodos , Dor/tratamento farmacológico , Tosse/induzido quimicamente , Tosse/prevenção & controle
11.
Anesth Analg ; 138(5): 1052-1062, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38416594

RESUMO

BACKGROUND: Robotic technique of surgery allows surgeons to perform complex procedures in difficult-to-access areas of the abdominal/pelvic cavity (eg, radical prostatectomy and radical hysterectomy) with improved access and precision approach. At the same time, automated techniques efficiently deliver propofol total intravenous anesthesia (TIVA) with lower anesthetic consumption. As both above are likely to bring benefit to the patients, it is imperative to explore their effect on postanesthesia recovery. Quality of Recovery-15 (QoR-15) is a comprehensive patient-reported measure of the quality of postanesthesia recovery and assesses compendious patients' experiences (physical and mental well-being). This randomized study assessed the effect of automated propofol TIVA versus inhaled desflurane anesthesia on postoperative quality of recovery using the QoR-15 questionnaire in patients undergoing elective robotic surgery. METHODS: One hundred twenty patients undergoing robotic abdominal surgery under general anesthesia (GA) were randomly allocated to receive propofol TIVA administered by closed-loop anesthesia delivery system (CLADS) (CLADS group) or desflurane GA (desflurane group). Postoperative QoR-15 score on postoperative day 1 (POD-1) and postoperative day 2 (POD-2) (primary outcome variables), individual QoR-15 item scores (15 nos.), intraoperative hemodynamics (heart rate, mean blood pressure), anesthesia depth consistency, anesthesia delivery system performance, early recovery from anesthesia (time-to-eye-opening, and time to tracheal extubation), and postoperative adverse events (sedation, postoperative nausea and vomiting [PONV], pain, intraoperative awareness recall) (secondary outcome variables) were analyzed. RESULTS: On POD-1, the CLADS group scored significantly higher than the desflurane group in terms of "overall" QoR-15 score (QoR-15 score: 114.5 ± 13 vs 102.1 ± 20.4; P = .001) and 3 individual QoR-15 "items" scores ("feeling rested" 7.5 ± 1.9 vs 6.4 ± 2.2, P = .007; "good sleep" 7.8 ± 1.9 vs 6.6 ± 2.7, P = .027; and "feeling comfortable and in control" 8.1 ± 1.7 vs 6.9 ± 2.4, P = .006). On the POD-2, the CLADS group significantly outscored the desflurane group with respect to the "overall" QoR-15 score (126.0 ± 13.6 vs 116.3 ± 20.3; P = .011) and on "5" individual QoR-15 items ("feeling rested" 8.1 ± 1.4 vs 7.0 ± 2.0, P = .003; "able to return to work or usual home activities" 6.0 ± 2.2 vs 4.6 ± 2.6, P = .008; "feeling comfortable and in control" 8.6 ± 1.2 vs 7.7 ± 1.9, P = .004; "feeling of general well-being" 7.8 ± 1.6 vs 6.9 ± 2.0, P = .042; and "severe pain" 9.0 ± 1.9 vs 8.1 ± 2.5, P = .042). CONCLUSIONS: Automated propofol TIVA administered by CLADS is superior to desflurane inhalation GA with respect to early postoperative recovery as comprehensively assessed on the QoR-15 scoring system. The effect of combined automated precision anesthesia and surgery (robotics) techniques on postoperative recovery may be explored further.


Assuntos
Anestésicos Inalatórios , Propofol , Procedimentos Cirúrgicos Robóticos , Masculino , Feminino , Humanos , Propofol/efeitos adversos , Desflurano/efeitos adversos , Anestésicos Intravenosos/efeitos adversos , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Anestesia Intravenosa/efeitos adversos , Anestesia Geral/efeitos adversos , Anestesia Geral/métodos , Dor/etiologia , Período de Recuperação da Anestesia , Anestésicos Inalatórios/efeitos adversos
12.
Eur J Pediatr ; 183(5): 2251-2256, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38407589

RESUMO

The purpose of this study is to evaluate the intracellular and extracellular volume before and after anesthesia in order to ascertain their variations and determine the potential utility of this information in optimizing intraoperative fluid administration practices. A bioimpedance spectroscopy device (body composition monitor, BCM) was used to measure total body fluid volume, extracellular volume, and intracellular volume. BCM measurements were performed before and after general anesthesia in unselected healthy children and adolescents visiting the Pediatric Institute of Southern Switzerland for low-risk surgical procedures hydrated with an isotonic solution. In 100 children and adolescents aged 7.0 (4.8-11) years (median and interquartile range), the average total body water increased perioperatively with a delta value of 182 (0-383) mL/m2 from pre- to postoperatively, as well as the extracellular water content, which had a similar increase with a delta value of 169 (19-307) mL/m2. The changes in total body water and extracellular water content significantly correlated with the amount of fluids administered. The intracellular water content did not significantly change.   Conclusion: Intraoperative administration of isotonic solutions results in a significant fluid accumulation in low-risk schoolchildren during general anesthesia. The results suggest that children without major health problems undergoing short procedures do not need any perioperative intravenous fluid therapy, because they are allowed to take clear fluids up to 1 h prior anesthesia. In future studies, the use of BCM measurements has the potential to be valuable in guiding intraoperative fluid therapy. What is Known: • Most children who undergo common surgical interventions or investigations requiring anesthesia are nowadays hydrated at a rate of 1700 mL/m2/day with an isotonic solution. • The use bioimpedance spectroscopy for the assessment of fluid status in healthy children has already been successfully validated. • The bioimpedance spectroscopy is already currently widely used in various nephrological settings to calculate fluid overload and determine patient's optimal fluid status. What is New: • Routine intraoperative fluid administration results in a significant fluid accumulation during general anesthesia in low-risk surgical procedures. • This observation might be relevant for children and adolescents with conditions predisposing to fluid retention. • In future studies, the use of BCM measurements has the potential to be valuable in guiding intraoperative fluid therapy.


Assuntos
Anestesia Geral , Composição Corporal , Hidratação , Humanos , Criança , Projetos Piloto , Masculino , Feminino , Anestesia Geral/métodos , Adolescente , Pré-Escolar , Hidratação/métodos , Espectroscopia Dielétrica/métodos , Água Corporal , Soluções Isotônicas/administração & dosagem , Impedância Elétrica , Suíça
13.
BMC Anesthesiol ; 24(1): 67, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38383307

RESUMO

BACKGROUND: This study aimed to investigate the effect of esketamine on the dose-effect relationship between remifentanil and the cardiovascular response to endotracheal intubation during target-controlled infusion (TCI) of propofol. METHODS: Patients underwent elective gynecological laparoscopic surgery under general anesthesia with endotracheal intubation, aged 18-65 years, American Society of Anesthesiologists class I or II, 18 kg/m2 ≤ body mass index ≤ 30 kg/m2, were randomly divided into the control (group C) and esketamine groups (group E). Before anesthesia induction, group E received an intravenous injection of 0.3 mg/kg of esketamine, while group C received an equal dose of physiological saline. TCI of propofol to the effect-site concentration (EC) of 3.0 µg/mL, and then TCI of remifentanil to the effect room and intravenous injection of rocuronium 0.6 mg/kg after MOAA/S was 0. Endotracheal intubation was performed after 2 min. Dixon's modified sequential method was used, and the initial EC of remifentanil was 3.0 ng/mL. The EC of remifentanil was determined according to the intubation response of the previous patient, with an adjacent concentration gradient of 0.3 ng/mL. The EC50 and EC95 values and their 95% confidence intervals (CIs) were determined using probit regression analysis. RESULTS: The EC50 for cardiovascular response inhibition to endotracheal intubation using remifentanil was 3.91 ng/mL (95% CI: 3.59-4.33 ng/mL) and EC95 was 4.66 ng/mL (95% CI: 4.27-6.23 ng/mL) with TCI of propofol 3.0 µg/mL. After intravenous administration of 0.3 mg/kg of esketamine, the EC50 of remifentanil was 3.56 ng/mL (95% CI: 3.22-3.99 ng/mL) and EC95 was 4.31 ng/mL (95% CI: 3.91-5.88 ng/mL). CONCLUSIONS: Combined with TCI of propofol 3.0 µg/mL for anesthesia induction, esketamine significantly reduced the EC50 and EC95 of remifentanil to inhibit the cardiovascular response to endotracheal intubation. TRIAL REGISTRATION: The trial was registered in the Chinese Clinical Trials Registry ( www.chictr.org.cn ; registration number: ChiCTR2200064932; date of registration:24/10/2022).


Assuntos
Ketamina , Propofol , Feminino , Humanos , Anestesia Geral/métodos , Anestésicos Intravenosos , Intubação Intratraqueal/métodos , Piperidinas , Remifentanil , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso
14.
Isr Med Assoc J ; 26(1): 24-29, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38420638

RESUMO

BACKGROUND: Pulmonary aspiration is a potentially lethal perioperative complication that can be precipitated by gastric insufflation. Face mask ventilation (FMV), a ubiquitous anesthetic procedure, can cause gastric insufflation. FMV with an inspiratory pressure of 15 cm H2O provides the best balance between adequate pulmonary ventilation and a low probability of gastric insufflation. There is no data about the effects of FMV > 120 seconds. OBJECTIVES: To investigate the effect of prolonged FMV on gastric insufflation. METHODS: We conducted a prospective observational study at a tertiary medical center with female patients who underwent oocyte retrieval surgery under general anesthesia FMV. Pre- and postoperative gastric ultrasound examinations measured the gastric antral cross-sectional area to detect gastric insufflation. Pressure-controlled FMV with an inspiratory pressure of 15 cm H2O was continued from the anesthesia induction until the end of the surgery. RESULTS: The study comprised 49 patients. Baseline preoperative gastric ultrasound demonstrated optimal and good image quality. All supine measurements were feasible. The median duration of FMV was 13 minutes (interquartile range 9-18). In the postoperative period, gastric insufflation was detected in only 2 of 49 patients (4.1%). There was no association between the duration of FMV and delta gastric antral cross-sectional area (ß -0.01; 95% confidence interval -0.04 to 0.01, P = 0.31). CONCLUSIONS: Pressure-controlled FMV with an inspiratory pressure of 15 cm H2O carries a low incidence of gastric insufflations, not only as a bridge to a definitive airway but as an alternative ventilation method for relatively short procedures in selective populations.


Assuntos
Insuflação , Máscaras Laríngeas , Feminino , Humanos , Anestesia Geral/efeitos adversos , Anestesia Geral/métodos , Insuflação/efeitos adversos , Máscaras Laríngeas/efeitos adversos , Respiração Artificial/efeitos adversos , Respiração Artificial/métodos , Estômago/diagnóstico por imagem , Estudos Prospectivos
15.
PeerJ ; 12: e16848, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38371374

RESUMO

Background: The Index of Consciousness (IoC) is a new monitoring index of anesthesia depth reflecting the state of consciousness of the brain independently developed by China. The research on monitoring the depth of anesthesia mainly focuses on propofol, and bispectral index (BIS) is a sensitive and accurate objective index to evaluate the state of consciousness at home and abroad. This study mainly analyzed the effect of IoC on monitoring the depth of sevoflurane anesthesia and the consistency and accuracy with BIS when monitoring sevoflurane maintenance anesthesia. Objective: To investigate the monitoring value of the Index of Consciousness (IoC) for the depth of sevoflurane anesthesia in laparoscopic surgery. Methods: The study population consisted of 108 patients who experienced elective whole-body anesthesia procedures within the timeframe of April 2020 to June 2023 at our hospital. Throughout the anesthesia process, which encompassed induction and maintenance using inhaled sevoflurane, all patients were diligently monitored for both the Bispectral Index (BIS) and the Index of Consciousness (IoC). We conducted an analysis to assess the correlation between IoC and BIS throughout the anesthesia induction process and from the maintenance phase to the regaining of consciousness. To evaluate the predictive accuracy of IoC and BIS for the onset of unconsciousness during induction and the return of consciousness during emergence, we employed receiver operating characteristic (ROC) curve analysis. Results: The mean difference between BIS and IoC, spanning from the pre-anesthesia induction phase to the completion of propofol induction, was 1.3 (95% Limits of Agreement [-53.4 to 56.0]). Similarly, during the interval from the initiation of sevoflurane inhalation to the point of consciousness restoration, the average difference between BIS and IoC was 0.3 (95% LOA [-10.8 to 11.4]). No statistically significant disparities were observed in the data acquired from the two measurement methodologies during both the anesthesia induction process and the journey from maintenance to the regaining of consciousness (P > 0.05). The outcomes of the ROC curve analysis disclosed that the areas under the curve (AUC) for prognosticating the occurrence of loss of consciousness were 0.967 (95% CI [0.935-0.999]) for BIS and 0.959 (95% CI [0.924-0.993]) for IoC, with optimal threshold values set at 81 (sensitivity: 88.10%, specificity: 92.16%) and 77 (sensitivity: 79.55%, specificity: 95.45%) correspondingly. For the prediction of recovery of consciousness, the AUCs were 0.995 (95% CI [0.987-1.000]) for BIS and 0.963 (95% CI [0.916-1.000]) for IoC, each associated with optimal cutoff values of 76 (sensitivity: 92.86%, specificity: 100.00%) and 72 (sensitivity: 86.36%, specificity: 100.00%) respectively. Conclusion: The monitoring of sevoflurane anesthesia maintenance using IoC demonstrates a level of comparability to BIS, and its alignment with BIS during the maintenance phase of sevoflurane anesthesia is robust. IoC displays promising potential for effectively monitoring the depth of anesthesia.


Assuntos
Anestésicos Inalatórios , Laparoscopia , Éteres Metílicos , Propofol , Humanos , Sevoflurano , Propofol/farmacologia , Estado de Consciência , Anestésicos Inalatórios/farmacologia , Éteres Metílicos/farmacologia , Monitorização Intraoperatória/métodos , Anestesia Geral/métodos
16.
JNMA J Nepal Med Assoc ; 62(269): 1-4, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38410011

RESUMO

Introduction: Postoperative sore throat is the second most common minor adverse event after general anaesthesia with endotracheal intubation. It is an uncomfortable and stressful sequel of tracheal intubation. The incidence of postoperative sore throat varies across different studies and type of anesthesia technique used. The aim of the study was to find out the prevalence of postoperative sore throat following general anaesthesia with endotracheal intubation in a tertiary care centre. Methods: A descriptive cross-sectional study was conducted among the patients who underwent surgery under general anaesthesia with endotracheal intubation from 1 December 2022 to 31 October 2023 after receiving ethical approval from the Institutional Review Committee. The anaesthesia technique was standardized in all the patients. A convenience sampling method was used. The point estimate was calculated at a 95% Confidence Interval. Results: Among 200 patients, postoperative sore throat was seen in 86 (43%) (36.14-49.86, 95% Confidence Interval) patients. The maximum reported time of sore throat was at a fourth postoperative hour 80 (93.02%). Conclusions: The prevalence of postoperative sore throat among patients undergoing surgery under general anaesthesia with endotracheal intubation was similar to the studies conducted in similar settings. Keywords: endotracheal intubation; general anaesthesia; prevalence.


Assuntos
Faringite , Complicações Pós-Operatórias , Humanos , Centros de Atenção Terciária , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Estudos Transversais , Anestesia Geral/efeitos adversos , Anestesia Geral/métodos , Faringite/epidemiologia , Faringite/etiologia , Intubação Intratraqueal/efeitos adversos
17.
J Cardiothorac Vasc Anesth ; 38(4): 911-917, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38281824

RESUMO

OBJECTIVES: Caval valve implantation (CAVI) represents a minimally invasive strategy for managing severe tricuspid regurgitation in high-risk patients unsuitable for surgical or transcatheter tricuspid valve implantation. This case series aimed to assess the anesthesia management challenges and outcomes associated with this procedure, seeking to generate insights that can inform and refine anesthesia protocols. DESIGN: A case series. SETTING: At a cardiac catheterization laboratory of a teaching hospital. PARTICIPANTS: Eight patients undergoing CAVI with the Tricvalve system INTERVENTIONS: The anesthetic protocol included preprocedural planning, fast-track general anesthesia, and postprocedural debriefing. Intraoperative management involved anesthesia depth monitoring, real-time guidance via transesophageal echocardiography, and hemodynamic stability maintenance. Postoperative analgesia involved preemptive intravenous paracetamol and morphine as needed. MEASUREMENTS AND MAIN RESULTS: No anesthesia-related or implantation-related complications were observed, with a mean procedure duration of 112 ± 44 minutes. The median hospital stay was 4 days, and only 1 patient required brief intensive care unit monitoring. Postoperative right shoulder pain was reported by half of the patients, and was managed with morphine bolus administration (average dose 4.75 ± 3.6 mg). All patients had the device correctly positioned, as confirmed by postoperative transthoracic echocardiograms. None of the patients required outpatient analgesic therapy upon discharge. CONCLUSIONS: The authors' study demonstrated the potential of TricValve implantation in effectively managing severe tricuspid regurgitation with no procedure-related complications and a 100% survival rate. A collaborative, interdisciplinary approach and targeted anesthesia management proved crucial for this success. Postoperative shoulder pain emerged as a frequent complication, whose pathogenesis is still not clear, and successfully was managed using targeted analgesic therapy.


Assuntos
Anestésicos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Tricúspide/cirurgia , Dor de Ombro , Anestesia Geral/métodos , Analgésicos , Derivados da Morfina , Resultado do Tratamento , Cateterismo Cardíaco/métodos
18.
Medicine (Baltimore) ; 103(2): e36855, 2024 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-38215085

RESUMO

INTRODUCTION: Inadvertent perioperative hypothermia (IPH), defined as core body temperature below 36°C, is associated with various complications. Shoulder arthroscopy is a risk factor of IPH. This study aimed to compare the incidence of IPH between general anesthesia (GA) and interscalene brachial plexus block (ISBPB) for shoulder arthroscopy. METHOD: Patients scheduled for shoulder arthroscopy were prospectively enrolled and randomly assigned to GA or ISBPB groups. The body temperature of the patients was measured from baseline to the end of anesthesia and in the post-anesthetic care unit to compare the incidence of IPH. RESULTS: Of the 114 patients initially identified, 80 were included in the study (GA = 40, ISBPB = 40). The incidence of IPH differed significantly between the groups, with GA at 52.5% and ISBPB at 30.0% (P = .04). Profound IPH (defined as < 35.0°C) occurred in 2 patients with GA. Upon arrival at the post-anesthesia care unit, the GA group exhibited a significantly lower mean body temperature (35.9 ±â€…0.6°C) than the ISBPB group (36.1 ±â€…0.2°C, P = .04). CONCLUSION: The incidence of IPH in the GA group was higher than that in the ISBPB group during shoulder arthroscopy, suggesting that ISBPB may be a preferable anesthetic technique for reducing risk of IPH in such procedures.


Assuntos
Anestésicos , Bloqueio do Plexo Braquial , Hipotermia , Humanos , Bloqueio do Plexo Braquial/efeitos adversos , Bloqueio do Plexo Braquial/métodos , Ombro/cirurgia , Estudos Prospectivos , Hipotermia/epidemiologia , Hipotermia/etiologia , Hipotermia/prevenção & controle , Artroscopia/efeitos adversos , Artroscopia/métodos , Incidência , Anestesia Geral/efeitos adversos , Anestesia Geral/métodos , Dor Pós-Operatória
19.
IEEE Trans Biomed Eng ; 71(5): 1607-1616, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38285584

RESUMO

OBJECTIVE: The study aims to investigate the relationship between amplitude modulation (AM) of EEG and anesthesia depth during general anesthesia. METHODS: In this study, Holo-Hilbert spectrum analysis (HHSA) was used to decompose the multichannel EEG signals of 15 patients to obtain the spatial distribution of AM in the brain. Subsequently, HHSA was applied to the prefrontal EEG (Fp1) obtained during general anesthesia surgery in 15 and 34 patients, and the α-θ and α-δ regions of feature (ROFs) were defined in Holo-Hilbert spectrum (HHS) and three features were derived to quantify AM in ROFs. RESULTS: During anesthetized phase, an anteriorization of the spatial distribution of AMs of α-carrier in brain was observed, as well as AMs of α-θ and α-δ in the EEG of Fp1. The total power ([Formula: see text]), mean carrier frequency ([Formula: see text]) and mean amplitude frequency ([Formula: see text]) of AMs changed during different anesthesia states. CONCLUSION: HHSA can effectively analyze the cross-frequency coupling of EEG during anesthesia and the AM features may be applied to anesthesia monitoring. SIGNIFICANCE: The study provides a new perspective for the characterization of brain states during general anesthesia, which is of great significance for exploring new features of anesthesia monitoring.


Assuntos
Anestesia Geral , Eletroencefalografia , Processamento de Sinais Assistido por Computador , Humanos , Eletroencefalografia/métodos , Anestesia Geral/métodos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Encéfalo/fisiologia , Algoritmos , Adulto Jovem , Idoso , Monitorização Intraoperatória/métodos
20.
BMC Anesthesiol ; 24(1): 6, 2024 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-38166574

RESUMO

BACKGROUND: To perform step-by-step analysis of the different factors (material, anesthesia technique, human, and location) that led to major pneumothorax during an infrequent pediatric cardiac MRI and to prevent its occurrence in the future. Anesthesia equipment used in a remote location is often different than those in operating rooms. For magnetic resonance imaging (MRI), ventilation devices and monitors must be compatible with the magnetic fields. During cardiac MRI numerous apneas are required and, visual contact with the patient is limited for clinical evaluation. Anesthesia-related barotrauma and pneumothorax are rare in children and the first symptoms can be masked. CASE PRESENTATION: A 3-year-old boy with atrial septal defect (ASD) and suspicious partial anomalous pulmonary venous return was anesthetized and intubated to perform a follow up with MRI. Sevoflurane maintenance and ventilation were performed using a circular CO2 absorber device, co-axial circuit, and 500 mL pediatric silicone balloon. Apneas were facilitated by Alfentanyl boluses and hyperventilation. A few moderated desaturations occurred during the imaging sequences without hemodynamic changes. At the end of the MRI, facial subcutaneous emphysema was observed by swollen eyelids and crackling snow neck palpation. A complete left pneumothorax was diagnosed by auscultation, sonography examination, and chest radiograph. Pneumo-mediastinum, -pericardium and -peritoneum were present. A chest drain was placed, and the child was extubated and transferred to the pediatric intensive care unit (PICU). Despite the anesthesiologist's belief that PEEP was minimal, critical analysis revealed that PEEP was maintained at a high level throughout anesthesia. After the initial barotrauma, repeated exposure to high pressure led to the diffusion of air from the pleura to subcutaneous tissues and mediastinal and peritoneal cavities. Equipment check revealed a functional circular circuit; however, the plastic adjustable pressure-limiting valve (APL) closed within the last 30° rotation. The balloon was found to be more rigid and demonstrated significantly reduced compliance. CONCLUSIONS: Anesthetists require proficiency is using equipment in non-OR locations and this equipment must be properly maintained and checked for malfunctions. Controlling the human factor risks by implementing checklists, formations, and alarms allows us to reduce errors. The number of pediatric anesthesia performed routinely appeared to be essential for limiting risks and reporting our mistakes will be a benefit for all who care about patients.


Assuntos
Barotrauma , Pneumotórax , Pré-Escolar , Humanos , Masculino , Anestesia Geral/efeitos adversos , Anestesia Geral/métodos , Apneia , Imageamento por Ressonância Magnética/efeitos adversos , Pneumotórax/diagnóstico por imagem , Pneumotórax/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...